null

NSF Certified Class II Type A2 Biosafety Cabinet With Detachable Stand - Various Sizes




Brand :

$6,500.00 - $8,000.00
SKU:
USA-BSC-

NSF Certified Class II Type A2 Biosafety Cabinet

A biosafety cabinet, also known as a biological safety cabinet or microbiological safety cabinet, is an enclosed and ventilated workspace used in laboratories to safely handle materials contaminated or potentially contaminated with pathogens. Its primary purpose is to protect laboratory workers and the environment from these harmful microorganisms.

The cabinet ensures safety by filtering all exhaust air through HEPA filters before releasing it, effectively removing bacteria and viruses. This differs from laminar flow clean benches, which direct unfiltered exhaust air towards the user and are not suitable for handling pathogenic agents. Similarly, a biosafety cabinet is distinct from fume hoods, as the latter doesn't offer the same level of environmental protection provided by HEPA filtration.

There are different classes of biosafety cabinets:

  • Class I cabinets offer personnel and environmental protection but not product protection, potentially leading to sample contamination due to inward airflow. They are often used for enclosing specific equipment or procedures that might produce aerosols.

  • Class II cabinets provide both sample and environmental protection as the makeup air is also HEPA-filtered. They come in different types (A1, A2, B1, B2, C1) based on specific requirements defined by standards.

As for the Ai 2 Ft Class II Type A2 biosafety cabinet features, it includes various specifications such as NSF certification, suitability for COVID-19 specimen handling, a motorized front glass viewing window with optional foot switch, dual HEPA filters with life indicators, UV light with a life indicator, waterproof in-chamber power sockets, large LCD display, easy-to-clean stainless steel chamber, and other functionalities for user convenience and safety.

Steps before and after using the biosafety cabinet involve closing the front glass panel, initiating UV light for 30 minutes for disinfection (users should vacate the room during this period), adjusting the glass panel to the recommended opening height while turning on air circulation for 10 minutes during operation, and finally, closing the glass panel and activating UV light for an additional 30 minutes for decontamination after use.

 

IMPORTANT GUIDELINES USING A BSC

  • No flammable and explosive substances (Building up of flammable material may cause an internal fire or explosion)
  • No volatile chemicals (May cause damage to HEPA filters to the point where it allows particles to leak through)
  • No toxic chemicals or materials (May reach room occupants)
  • No open flame (Will disrupts air flow patterns)
  • Minimal use (10mL or less) of decontaminant, such as 70% isopropyl or ethyl alcohol is allowed.
  • We recommend using the following for disinfecting the surfaces of a BSC, depending on the agent to be controlled: Sodium hypochlorite (bleach), Ilodophors (Wescodyne), Phenolics (Hilphene, Vespene) and Quaternary ammonium compounds (Conflikt, EndbacII)
  • If gaseous, vaporized or aerosolized chemicals must be generated in a BSC, you should assure yourself that the quantity being generated will NOT cause a flammable or toxic risk.

 

 

 

Model                  

USA-BSC-3FT

USA-BSC-4FT

USA-BSC-6FT

External Size (W*D*H) (mm)

1087*775*2265

1383*775*2295

1873*775*2295

External Size (W*D*H) (in)

42.8" X 30.5" X 89.2"

54.5" X 30.5" X 90.4"

73.8" X 30.5" X 90.4"

Internal Size (W*D*H) (mm)

910*600*660

1210*600*660

1700*600*660

Internal Size (W*D*H) (in)

36" X 23.6" X 26"

48" X 23.6" X 26"

67" X 23.6" X 26"

Work Surface  Height

750mm

Max Opening 

520mm(20.5’’)

550mm (22’’)

550mm (22’’)

Tested Opening 

Safety height 254mm (10’’) 

Inflow 

445m3/h(259cfm)

587m3/h(346cfm)

824m3/h(485cfm)

Down flow 

60%:649m3/h(382cfm)

60%:863m3/h(507cfm)

60%:1212m3/h(713cfm)

Exhaust 

40%:441m3/h(259cfm)

40%:587m3/h(346cfm)

40%:824m3/h(485cfm)

Front Window 

Motorized. Two-layer laminated toughened glass ≥5mm. Anti UV

HEPA Filter    

Two, 99.995% efficiency at 0.3μm, filter life indicator

Filter Guard Type 

Aluminum alloy frame

Aluminum alloy frame

Aluminum alloy frame

Noise 

NSF 49≤67 dB

NSF 49≤67 dB

NSF 49≤67 dB

Illumination 

≥1000Lux

≥1000Lux

≥1000Lux

Display 

LCD Display

LCD Display

LCD Display

Waterproof Socket  

2, Total consumption:≤500W

2, Total consumption:≤500W

2, Total consumption:≤500W

Tap 

Water tap*1, Gas tap *1

Water tap*1, Gas tap *1

Water tap*1, Gas tap *1

Ground Resistance 

≤ 0.10Ω

≤ 0.10Ω

≤ 0.10Ω

Power Supply 

AC220V±10%, 50/60Hz; 110V±10%, 60Hz, Full load Amps: 9A, BTU/Hr: 1689

Consumption 

400W

500W

700W

Alarm 

Abnormal airflow velocity; Filter replacement; Front window at unsafe height.

DC Motor 

One ECM motor, 110V& 220V acceptable, Speed adjustable, high efficiency and low power consumption

Material 

Working area: 304stainless steel/  Frame and Decorative Plate: cold-rolled steel with anti-bacteria power coating

UV Lamp   

20W

30W

40W

 

Germicidal UV lamp, Emission of 253.7 nanometers for most efficient decontamination

Illuminating Lamp 

10W*2 | LED lamp

18W*2 | LED lamp

22W*2 | LED lamp

Standard Accessory 

Illuminating lamp, UV lamp *2, Base stand, SS water & gas taps, Drain valve, Waterproof sockets, Stainless Steel I.V. Bar with 10 hooks

Optional Accessory 

Armrest, Airflow tester, Formalin fumigation sterilizer, Infrared sterilizer, Electric height adjustable base stand, Remote control Electric height adjustable base stand, Remote control

Package Size  (W*D*H)

1240*1060*1840 (mm) | 49" X 42" X 72.5" (in)

1540*1080*1900 (mm) | 60.6" X 42.5" X 75" (in)

2020*1080*1900 (mm) | 79.5" X 42.5" X 75" (in)

Gross Weight(kg \ lbs)

270 kg | 595lbs

340 kg | 750lbs

370 kg | 815lbs

 

 

 

 

 

For Technical Support, Questions, or Other Issues Please Email or Call Us!

usa-lab-logo-with-phone-number.jpg

1 Year Warranty