HUBER Unistat T340 with Pilot ONE
(Please Note: There is a 2 - 3 weeks lead time)
The Unistat range inspires with unique thermodynamic properties and a range of functions to meet the highest demands. Unistat technology guarantees precise, reproducible temperature control results, the shortest possible heating and cooling times and large temperature ranges without the need for fluid change. All Unistats are fitted with the innovative Pilot ONE controller with a 5.7“ touchscreen colour display and easy menu navigation. All important parameters can be seen at a glance and temperature curves are displayed in graphic real time. Unistats are equipped with the most up-to-date pump technology for optimal heat transfer. The pump self regulates to ensure the best possible circulation and flow and delicate glass reactors are protected from breakage by the pumps soft start-up feature. Unistat technology impresses as a result of economic operation with reduced operating costs and efficient energy management. Because Unistats are hydraulically sealed, the service life of the temperature control fluid is dramatically increased by preventing oil loss through vapours and oxidation, further saving resources. Unistats are fitted with extensive safety equipment and are therefore suitable for unsupervised continuous operation. Relevant operating conditions are constantly monitored and the system is switched off if necessary or with the process safety feature the emergency cooling circuit is activated.
The new multi-touch controller Pilot ONE offers a brilliant 5.7" touchscreen with graphic functions and a comfortable navigation menu. All important operating parameters and temperature values are neatly displayed on the touchscreen. Thanks to the new favourites menu, the one-click operation and the integrated technical glossary the operation is very easy, just like on a smartphone. Integrated USB and Ethernet ports allows connection to a PC or network, e.g. for remote control or data transmission
Unistat T340 Specifications |
|
General Information & Temperature Controller |
|
Temperature range |
65...300 °C |
Temperature stability |
±0.01 °C |
Temperature control |
TAC, self-optimizing (True Adaptive Control) |
Display resolution |
0.01 °C |
Alarm message |
optical, acoustical |
Controller |
|
Safety class |
III / FL |
Protection class |
IP20 |
Dimensions (W x D x H) |
31.5 x 41.73 x 62.99 inches |
Weight |
? kg | ? pounds |
Heating / Cooling Capacity |
|
Heating capacity |
43 - 48 kW |
Circulation Pump |
|
Pressure pump max. |
90 lpm ; 5.5 bar | 23.78 gpm ; 79.75 psi |
Pump connection |
M38x1,5 AG male |
Permissible viscosity |
50 mm²/s |
Pump speed adjustable |
Yes |
Connections |
|
Pt100 connection |
Pt100 |
Analogue input |
via optional Com.G@te |
Analogue output |
via optional Com.G@te |
Digital interface |
RS232, Ethernet, USB Device, USB Host |
Operating Data |
|
Permissible ambient temp. |
5...40 °C |
Volume of expansion |
56 Liters | 14.8 gal |
Power supply |
380-460V 3~ 50/60Hz |
For Technical Support, Questions, or Other Issues Please Email or Call Us!
"5.0 Warranty
5.1 Defects in the delivered goods, insofar as they can be detected during inspection in the ordinary course of business, shall be notified by us within 10 days of receipt of the goods. Defects which could not be detected during such an inspection shall be notified to us within 10 days of becoming aware of them. To meet the deadline, it is sufficient to send the notice of defects to you.
5.2 We shall be entitled to the statutory warranty claims against you. You shall be liable to us to the extent provided by law, in particular for all damages arising from the breach of a contractual obligation. In the event of subsequent performance, we shall have the exclusive right to choose between rectification of defects and new production/performance.
5.3 The limitation period for our claims and rights due to defects in the deliveries/services - irrespective of the legal grounds - shall be 4 years. This period shall also apply if the claims are not related to a defect. Longer statutory limitation periods shall remain unaffected, as shall the provisions on the commencement of the limitation period, the suspension of the running of the limitation period, the suspension and the recommencement of limitation periods."